Welcome Report Control Admin
Sys Config
Tech-Ref
185
scheduled 'closing' time, area keypads will beep
to remind staff to either arm the area and exit, or
delay the closing time (worklate). If neither of
these actions occur, an alarm can be
transmitted, and/or the area can be armed
automatically (as per settings to follow).
Tip:
Pause the mouse cursor over a schedule in the
list to see the settings for that schedule.
To define a schedule, refer to "Schedules for User
Access and Area Automation".
A programmable output can be set to signal when the
area closing time is approaching. For details, refer to
"Programmable Outputs".
- Out of Schedule:
The length of time before the
area will automatically 're-close' after an
'emergency off' is performed
(i.e., being disarmed
outside
of the schedule).
This limits the time that an "Emergency Off" can
remain in effect.
- In Schedule:
The length of time before the area
will automatically 're-close' after being disarmed
inside
of the schedule. This allows limiting the
time that authorized users can remain in the
area during the schedule (e.g., cash machines,
vaults, etc.).
- Work Late Input:
When someone presses a
work-late button in this area (during the 'pre-arm
cycle), the scheduled closing time with be set as
{
value selected here
} from the present time.
Note:
A worklate button is a custom input point with
its 'pre-process' set as "Worklate". To define a 'work
late' input-point, refer to "Input Points—Custom Point
Types", and "Input Points—Monitored Sensors".
- Limit Work Late to Midnight:
User's ability to
'Work Late' (i.e., override the scheduled 'Close'
time) for this area will be limited to not extend
beyond midnight.
- Transmit Fail to Close:
Transmit a "Fail-to-
Close" to the monitoring station if the area has
not been armed at the scheduled closing time.
- Auto Arm on Fail to Close:
The area will auto-
arm at the scheduled closing time. This cannot
be used in conjunction with 'Stay on Fail to Exit'
(described above).
-------------------------
- Allow Out of Schedule Opens:
Whether or not
users
without
'24-hr' authority will be able to
gain entry and/or disarm this area outside of
its
open/close schedule, and/or adjust the area
closing time (i.e., 'worklate') after
their
schedule
has expired. (For a non- scheduled area, this
concept does not apply, since only 'Disarm'
authority would be required.) For details on user
authorities, refer to "Authorities for
Users/Entrants".
Stay-Off-Stay Scheduling
- Schedule:
A schedule to be associated with
automated stay/off/stay arming in this area (also
see next setting).
Tip:
Pause the mouse cursor over a schedule in the
list to see the settings for that schedule.
- Auto Stay Mode:
Specifies that the area will
automatically switch from 'Stay' to 'Off', and then
'Off' to 'Stay', in-sync with schedule chosen
above. This will not occur if the area is fully
armed (ON) at the applicable times.
+ None:
Disables this feature (same as selecting
"None" for the schedule.
+ Non secure Disarm to Off:
The area will disarm
(e.g., at the start of the day) if it is in 'stay' mode at
the specific time;
+ Secure Disarm to Off:
For the area to be
disarmed (to off) at the scheduled time, the area
must be armed to 'Stay', and it must have been fully
armed once since the last cycle (ensures someone
was in the facility to arm the area at some time);
+ Disarm to Off Pending First Valid User:
The area
will disarm to off if it is in 'stay' mode at the
scheduled time, but the change will not occur until a
valid user is granted access into the area.
Miscellaneous
- LCD Name:
A shorter version of the name to be
displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).
- Require Function Key PIN:
Whether or not the
programmable hot-keys 6-9 & 0 will require a
user with "Function Key" authority to be logged
in. (Function keys 1-5 do not require ID/PIN
entry, except at a portable/wireless arming
keypad).
Tip:
This setting is recommended to help protect
against false alarms.
For details on
using
the function keys on a system
LCD keypad, refer to the MONITOR AFx
(panel/keypad) User's Guide.
What each function key does is set up under
"Programmable Outputs".
To enable function-key authority for a user, refer to the
"Function Keys" setting under "Authorities for
Users/Entrants".