22-9058 v2.1
Welcome PCPanel IP
Cent. Mon. with IP
Ref. Topics
25
3.5 Security IP Receiver Software (SIP)
(at the Central Monitoring Facility)
3.5.1 Introduction
The IP receiver software polls up to 1000
panel connections (IP boards), and relays
the messages it receives to alarm
automation software (MAS or equiv.) using
the SG-DLR2 protocol.
Each panel is referenced by the ”Digital
Account ID” which is displayed as the account # in the receiver software. This is set through
the system communications screen of the Director software, or with S001:00 through an LCD
keypad.
3.5.2 Connection between the IP Receiver PC and the Automation PC
Connect through an available serial com port (RS-232) using wiring that is compatible with the
automation software. (Tip: The serial com port being used needs to be set in the IP receiver
software as well.)
3.5.3 Connection Mode Options
The IP Receiver software can connect using any of these modes:
• Auto-Mode: (Single-Panel Only). This uses only the IP address and port number of the IP
Interface board. All other settings are taken care of automatically avoiding most common
problems including address duplication etc.
Note
: With this setting, leave the "Connect Number" blank at the IP Receiver software.
•
Main Panel Motherboard Serial Number Mode: (Single panel or shared connection.). This
uses the serial number of the panel, plus the IP address and port number of the IP Interface
board. This is the easiest approach that supports a multi-panel connection.
The panel's Serial Number:
+ Is defined through the Director software under: Configuration⇒System ⇒Communication
(can be viewed through an LCD keypad under S005:00, 1
st
field) if the Memory Model is less
than ≤ 4.
+ Must be entered as the "Connect Number" through the IP Receiver
software.
• Digital Account ID/Number: (Single-panel or shared connection). This uses the "Digital Account
ID" of the panel, plus the IP address and port number of the IP Interface board.
The digital account number:
+ Must be unique for each panel.
+ Is defined through the Director software under: Configuration⇒System ⇒Communication
(or through an LCD keypad under S001:00 (2
nd
field) if the Memory Model is less than ≤ 4.
+ Must
also be entered as the "Connect Number" through the IP Receiver software,
and as the
"Account Number" through the automation software;
• SIP Address
: (Single-panel or shared connection). This uses the optional panel
setting "SIP Address", plus the IP address and port number of the IP Interface board.
The panel SIP Address:
+ Must be unique for each panel on a shared connection (i.e. on the same IP board)
01 – 80 (00 = not used)
+ Is defined through the Director software under: Configuration ⇒System ⇒Communication
(or through an LCD keypad under S005:02 (2
nd
field) if the Memory Model is less than ≤ 4.
+ Must
also be entered as the "Connect Number" through the IP Receiver software.
Director PC: The Security IP Receiver software cannot
be run on the MONITOR ISM / AFx Director PC. A
separate PC will need to be dedicated
Activation Key: The IP receiver software requires an
activation key on the parallel port of the PC.